TRACC-PHYSIO: Time-Domain Resolution-Aligned Cross-Correlation to Estimate PHYSIOlogical Coupling and Time Delays in Dynamic MRI.
5 blocks of code here have a permanent identifier (oscr:b:…), listed with the matches below: citable for good, with a page of its own. Select a match and press Cite to copy it. What a block identifier is.
The 9 matches · 2 of them tie a paragraph to a whole file without given lines: weak matches, whose lines are not tinted
- [1] § Methods › Simulation‐Based Validation of TRACC‐PHYSIO › Physiological Signal Generation ↔ TRACC_simulation_code/simulated_signal_examples_wFigure.m, the whole file · a weak match · score 0.79 · simulated respiratory signal, simulated PPG, simulated MR signal, respiratory ratio, PPG signal, SNR · block
oscr:b:53ZKDQN5AV66F-Q· Report a mismatch - [2] § Methods › Simulation‐Based Validation of TRACC‐PHYSIO › Physiological Signal Generation ↔ TRACC_simulation_code/respiration_generation.m, lines 5 to 37 · score 0.77 · respiratory belt signals, simulated respiratory belt, respiratory rate, sinusoidal, asymmetry, breathing · block
oscr:b:E9D4VMV2XAK5P-4· Report a mismatch - [3] § Methods › Simulation‐Based Validation of TRACC‐PHYSIO › Simulation Experiments ↔ TRACC_simulation_code/simulated_signal_examples_wFigure.m, the whole file · a weak match · score 0.69 · cardiac respiratory, respiratory ratios, simulated signals, MR signal, physiological signals, RR · block
oscr:b:53ZKDQN5AV66F-Q· Report a mismatch - [4] § Methods › TRACC‐PHYSIO Method ↔ TRACC_realData_code/get_TRACC_Cardiac_bySlice.m, lines 20 to 64 · score 0.68 · Pearson correlation coefficient, cross correlation, TRACC Cardiac, shifts, temporal, PHYSIO · block
oscr:b:SZ0JS5MPFG5ZB-4· Report a mismatch - [5] § Methods › Simulation‐Based Validation of TRACC‐PHYSIO › Physiological Signal Generation ↔ TRACC_simulation_code/respiration_generation.m, lines 5 to 37 · score 0.67 · respiration belt signal, simulated respiratory signal, respiration rate, breaths, minute, amplitude · block
oscr:b:E9D4VMV2XAK5P-4· Report a mismatch - [6] § Methods › Simulation‐Based Validation of TRACC‐PHYSIO › Synthetic MR Signal Generation ↔ TRACC_simulation_code/Example_TRACC_Cardiac_simulation.m, lines 17 to 99 · score 0.56 · imaging speeds, downsampled, MR signal, physiological signal, fast, noise · block
oscr:b:0BHY83Q35TC4Y-L· Report a mismatch - [7] § Methods › Simulation‐Based Validation of TRACC‐PHYSIO › Simulation Experiments ↔ TRACC_simulation_code/Example_TRACC_Cardiac_simulation.m, lines 17 to 99 · score 0.56 · simulated signals, composition, MR signal, physiological signals, shift, TimeDelay · block
oscr:b:0BHY83Q35TC4Y-L· Report a mismatch - [8] § Methods › TRACC‐PHYSIO Method ↔ TRACC_realData_code/get_TRACC_Cardiac_bySlice.m, lines 20 to 64 · score 0.55 · Correlation Coefficient, cross correlation, temporal, TRACC, PHYSIO, signal · block
oscr:b:SZ0JS5MPFG5ZB-4· Report a mismatch - [9] § Methods › Simulation‐Based Validation of TRACC‐PHYSIO › Physiological Signal Generation ↔ TRACC_simulation_code/pulse_generation.m, lines 27 to 72 · score 0.51 · heart rate variability, beat, HRV, simulations, physiologically, cardiac · block
oscr:b:7KYHCZMCN6Z8J-P· Report a mismatch
Paper
Loaded from Europe PMC by your browser; OSCR does not store it: doi.org · Europe PMC
The paper is loaded when this pane is shown.
The authors' code
MATLAB · 133 lines · 3.7 KB · MIT · 2 matches
- % Written by: Adam Wright
- % Email: [email hidden]
- % Example generation and plots of physiological signals -- PPG and Resp.
- %Generate PPG data
- fs = 400; %Hz
- HR = 60; %bpm
- HRV = 50; %ms -- this will be slightly variable for the SDNN HRV measure
- T = 600; %s -- ten minutes of data
- N = T/(1/fs);
- time = linspace(0,T-1/fs,N);
- %Get simulated PPG signal
- pulse_sim = pulse_generation(HR,HRV,T,fs);
- %Generate Resp data
- RR = 12; %bpm
- RRV = 500; %ms -- -- this will be slightly variable for the SDNN RRV measure
- %Get simulated Resp signal
- resp_sim = respiration_generation(RR,RRV,T,fs);
- %Simulated MR signal with 2:1 cardiac-respiratory ratio, with a TR of 1
- %sec and acquisition time of 360 s.
- cardiac_amp = 2;
- resp_amp = 1;
- %Start with mixed physiological signal with longer acquisition time and no
- %noise and fs = 400 Hz
- [mixed_physio, ~, ~] = generatePhysiologicalSignal(HR, HRV, RR, RRV, cardiac_amp, resp_amp, T, fs);
- TR = 1; %1 sec
- T_mr = 360;
- fs_mr = 1/TR;
- N_mr = fs_mr*T_mr;
- %Sample the mr signal 5 seconds after the start of the 10 minute simulated mixed
- %physiology signal (this avoids issues when longer lags are applied to have
- %a non defined physiological signal). In real data the physiological signal
- %recordings are recorded before and aftet the MR acquition, if this isn't
- %the case the edge effects need to be accounted for properly.
- t_start = ceil(5/TR);
- t_mr = linspace(t_start,T_mr+t_start-TR,N_mr);
- t_mr_plot = t_mr-t_start;
- [~,idx_in_mixed] = ismembertol(t_mr, time, 0.000001);
- %Getting the mr signal with proper TR acquisitions
- mr_simulated_noNoise = mixed_physio(idx_in_mixed);
- % Add noise with a certain SNR.
- SNR_dB = 20;
- mr_signal_power = mean(mr_simulated_noNoise.^2);
- noise_power = mr_signal_power / (10^(SNR_dB / 10)); %Noise power needed for a certain SNR
- noise = sqrt(noise_power)* randn(size(mr_simulated_noNoise)); %Generate noise
- %mr signal with noise
- mr_simulated_wNoise = mr_simulated_noNoise + noise;
- %Get freqeuncy spectrums for physiological and MR signals
- f_physio = (0:N-1)*(fs/N);
- f_mr =(0:N_mr-1)*(fs_mr/N_mr);
- %Calculate the pulse frequency spectrum
- fft_pulse = abs(fft(pulse_sim) / N);
- fft_pulse(2:ceil(N/2)) = 2*fft_pulse(2:ceil(N/2));
- %Calculate the resp frequency spectrum
- fft_resp = abs(fft(resp_sim) / N);
- fft_resp(2:ceil(N/2)) = 2*fft_resp(2:ceil(N/2));
- %Calculate the mr frequency spectrum
- fft_mr = abs(fft(mr_simulated_wNoise) / N_mr);
- fft_mr(2:ceil(N_mr/2)) = 2*fft_mr(2:ceil(N_mr/2));
- fontSize = 12;
- %Figure
- h = figure('Color','w', 'Visible', 'on');
- set(h, 'Position', [173 147 1150 657]);
- t = tiledlayout(3, 5, 'TileSpacing', 'loose');
- nexttile([1 3])
- plot(time,pulse_sim,'LineWidth',2);
- xlim([0 10])
- ylim([-1.5 1.5])
- xlabel('Time [s]')
- ylabel('PPG Signal')
- title('Simulated PPG Signal')
- set(gca, 'FontSize', fontSize)
- nexttile([1 2])
- plot(f_physio(1:ceil(N/2)),fft_pulse(1:ceil(N/2)),'LineWidth',1.5)
- xlim([0 5])
- xlabel('Frequency [Hz]')
- ylabel('PPG Amplitude')
- set(gca, 'FontSize', fontSize)
- nexttile([1 3])
- plot(time,resp_sim,'LineWidth',2);
- xlim([0 30])
- ylim([-1.5 1.5])
- xlabel('Time [s]')
- ylabel('Resp Signal')
- title('Simulated Respiration Signal')
- set(gca, 'FontSize', fontSize)
- nexttile([1 2])
- plot(f_physio(1:ceil(N/2)),fft_resp(1:ceil(N/2)),'LineWidth',1.5)
- xlim([0 1])
- xlabel('Frequency [Hz]')
- ylabel('Resp Amplitude')
- set(gca, 'FontSize', fontSize)
- nexttile([1 3])
- plot(t_mr_plot, mr_simulated_wNoise, 'LineWidth',2)
- xlim([0 60])
- ylim([-4 4])
- xlabel('Time [s]')
- ylabel('MR Signal')
- title('Simulated MR Signal w/Noise (TR = 1s, Acq duration = 360 s)')
- set(gca, 'FontSize', fontSize)
- nexttile([1 2])
- plot(f_mr(1:ceil(N_mr/2)),fft_mr(1:ceil(N_mr/2)),'LineWidth',1.5)
- xlim([0 1])
- xlabel('Frequency [Hz]')
- ylabel('MR Amplitude')
- set(gca, 'FontSize', fontSize)
simulated_signal_examples_wFigure.m at commit 01fa2f3, under MIT · at the source
Overview
- Department of Radiology and Imaging Sciences, Indiana University School of Medicine, Indianapolis, Indiana, USA
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA
Abstract
Purpose: To validate a method to assess cardiac and respiratory brain pulsations in slowly sampled dynamic MR scans. Cardiac and respiratory pulsations are key drivers of neurofluid circulation. However, resolving their temporal dynamics requires fast imaging, which is not achievable in many dynamic MR acquisitions.
Methods: We systematically validated TRACC‐PHYSIO, a Time‐domain Resolution‐Aligned Cross‐Correlation framework for estimating physiological coupling and time delays in dynamic MRI. This method uses simultaneously recorded cardiac and respiratory waveforms as external references and applies time‐shifted cross‐correlation to estimate physiological coupling strength and relative pulse delay in dynamic MRI data. Two metrics are derived: Peak Coupling Coefficient (Peak CorrCoeff), which quantifies coupling strength, and TimeDelay, which estimates the relative arrival time of the physiological impulse in the brain. TRACC‐PHYSIO was first evaluated with in vivo fMRI (TR = 363 ms) by comparing the Peak CorrCoeff with physiological bandpower derived from spectral analysis. Performance was further assessed using simulations of realistically modeled dynamic MR signals across repetition time (TR = 50–3000 ms) and acquisition durations (60–360 s).
Results: In fMRI, TRACC‐derived cardiac and respiratory Peak CorrCoeff were strongly associated with their respective spectrum‐derived physiological bandpower (all tests Pearson r > 0.90). In simulations, both Peak CorrCoeff and TimeDelay were estimated with no mean bias and low temporal errors across TRs and acquisition durations.
Conclusion: TRACC‐PHYSIO is a validated time‐domain framework for quantifying cardiac and respiratory coupling strength and estimating millisecond‐scale relative pulse delays in standard dynamic MR acquisitions.
Reproduced under the paper's license (CC BY), from the paper cited above.
Repositories
Its files are read in the Code ↔ Paper reader above, with 9 matches between paragraphs and lines of code.
Wen-Imaging-Lab/TRACC_PHYSIO
01fa2f3e269c00858e5e1a35ba2511486a1ea868, 19 March 2026Availability: 1 check, the latest on 28 September 2026: the link answers
- 28 September 2026: the link answers
14 files
- TRACC_realData_code/
get_TRACC_Cardiac_bySlic , MATLAB, 64 lines, 2 matchese.m - TRACC_realData_code/
loadData.m , MATLAB, 15 lines - TRACC_realData_code/
main_TRACC_Cardiac.m , MATLAB, 144 lines - TRACC_realData_code/
ppg_analysis.m , MATLAB, 180 lines - TRACC_realData_code/
readCMRRPhysio.m , MATLAB, 448 lines - TRACC_realData_code/
save_physio.m , MATLAB, 5 lines - TRACC_simulation_code/
Example_TRACC_Cardiac_si , MATLAB, 101 lines, 2 matchesmulation.m - TRACC_simulation_code/
generatePhysiologicalSig , MATLAB, 58 linesnal.m - TRACC_simulation_code/
physio_traccc.m , MATLAB, 66 lines - TRACC_simulation_code/
pulse_generation.m , MATLAB, 72 lines, 1 match - TRACC_simulation_code/
respiration_generation.m , MATLAB, 70 lines, 2 matches - TRACC_simulation_code/
simulated_signal_example , MATLAB, 133 lines, 2 matchess_wFigure.m - LICENSE, License, 21 lines
- README.md, Text, 30 lines
Zenodo 18762411
Availability: 1 check, the latest on 28 September 2026: the link answers (HTTP 200)
- 28 September 2026: the link answers (HTTP 200)
wright-adam/TRACC_PHYSIO
01fa2f3e269c00858e5e1a35ba2511486a1ea868, 19 March 2026Availability: 1 check, the latest on 28 September 2026: the link answers
- 28 September 2026: the link answers
14 files
- TRACC_realData_code/
get_TRACC_Cardiac_bySlic , MATLAB, 64 linese.m - TRACC_realData_code/
loadData.m , MATLAB, 15 lines - TRACC_realData_code/
main_TRACC_Cardiac.m , MATLAB, 144 lines - TRACC_realData_code/
ppg_analysis.m , MATLAB, 180 lines - TRACC_realData_code/
readCMRRPhysio.m , MATLAB, 448 lines - TRACC_realData_code/
save_physio.m , MATLAB, 5 lines - TRACC_simulation_code/
Example_TRACC_Cardiac_si , MATLAB, 101 linesmulation.m - TRACC_simulation_code/
generatePhysiologicalSig , MATLAB, 58 linesnal.m - TRACC_simulation_code/
physio_traccc.m , MATLAB, 66 lines - TRACC_simulation_code/
pulse_generation.m , MATLAB, 72 lines - TRACC_simulation_code/
respiration_generation.m , MATLAB, 70 lines - TRACC_simulation_code/
simulated_signal_example , MATLAB, 133 liness_wFigure.m - LICENSE, License, 21 lines
- README.md, Text, 30 lines
The paper's code and data availability statement is in the Data section.
Tracing map
Proposed by the machine: these links were found in the paper and verified at the source, without human review. The map will receive a Zenodo DOI once one of the paper's authors has validated it with their ORCID.
What the map holds:
- 3 repositories of the authors' code, each at its verified commit, with its license and how the link was found in the paper;
- 24 scripts, each with its path and the digest of its content;
- 9 matches between paragraphs of the paper and lines of the code (method lexical-v1);
- neither the text of the paper nor the code itself.
Its JSON (tracing-map.json) is deposited on Zenodo with its DOI once the map is validated.
Data
Data links
- zenodo:18762411, Zenodo; found in “Data Availability Statement”; this record also holds the authors' code (see Code)
Data Availability Statement
Code for the TRACC‐PHYSIO method and the simulated signal generation are available on GitHub (https://
Reproduced under the paper's license (CC BY), from the paper cited above.
Versions
The history of this record: each version stored by the harvester or made by a correction of its authors or of the maintainers of its code, and what changed in its facts. The texts of the paper (its abstract, its availability statements) are not part of it; versions that changed only those are not listed.
Version 2, 28 September 2026
- Publisher: n/a → Wiley
Version 1, 28 September 2026: the first record
Recorded: type, language, journal, volume, issue, pages, dates, 4 authors, 6 keywords, 9 MeSH terms, 4 funders, 26 references.
Cite
This paper
Wright, A. M., Zhang, J., Tong, Y., & Wen, Q. (2026). TRACC-PHYSIO: Time-Domain Resolution-Aligned Cross-Correlation to Estimate PHYSIOlogical Coupling and Time Delays in Dynamic MRI. Magnetic resonance in medicine, 96(4), 1605-1616. https://
BibTeX
@article{wright2026tracc
author = {Wright, Adam M and Zhang, Jianing and Tong, Yunjie and Wen, Qiuting},
title = {{TRACC-PHYSIO: Time-Domain Resolution-Aligned Cross-Correlation to Estimate PHYSIOlogical Coupling and Time Delays in Dynamic MRI}},
journal = {Magnetic resonance in medicine},
year = {2026},
month = may,
volume = {96},
number = {4},
pages = {1605--1616},
publisher = {Wiley},
issn = {0740-3194},
doi = {10.1002/
url = {https://
pmid = {42178506},
pmcid = {PMC13419326}
}
RIS
TY - JOUR
AU - Wright, Adam M
AU - Zhang, Jianing
AU - Tong, Yunjie
AU - Wen, Qiuting
TI - TRACC-PHYSIO: Time-Domain Resolution-Aligned Cross-Correlation to Estimate PHYSIOlogical Coupling and Time Delays in Dynamic MRI
T2 - Magnetic resonance in medicine
J2 - Magn Reson Med
PY - 2026
DA - 2026/
VL - 96
IS - 4
SP - 1605
EP - 1616
SN - 0740-3194
PB - Wiley
DO - 10.1002/
UR - https://
LA - en
ER -
CSL-JSON
{
"id": "10.1002/
"type": "article-journal",
"title": "TRACC-PHYSIO: Time-Domain Resolution-Aligned Cross-Correlation to Estimate PHYSIOlogical Coupling and Time Delays in Dynamic MRI",
"container-title": "Magnetic resonance in medicine",
"author": [
{
"family": "Wright",
"given": "Adam M"
},
{
"family": "Zhang",
"given": "Jianing"
},
{
"family": "Tong",
"given": "Yunjie"
},
{
"family": "Wen",
"given": "Qiuting"
}
],
"container-title-short":
"volume": "96",
"issue": "4",
"page": "1605-1616",
"DOI": "10.1002/
"PMID": "42178506",
"PMCID": "PMC13419326",
"ISSN": "0740-3194",
"publisher": "Wiley",
"URL": "https://
"language": "en",
"issued": {
"date-parts": [
[
2026,
5,
24
]
]
}
}
The tracing map gets a citation of its own once an author has validated it and it has a DOI.
Similar papers
The papers with a page that share the most with this one: the tools found in their code, their categories, datasets, cited references and authors, the rarest counting most.
- [1] doi:10.1162/imag.a.969
- An fMRI approach to assess intracranial arterial-to-venous cardiac pulse delay in aging.Journal: Imaging neuroscience (Cambridge, Mass.)In common: fMRI, 9 references, 2 authors
- [2] doi:10.1016/j.neuroimage.2025.121502 [code]
- HyPER: Region-specific hypersampling of fMRI to resolve low-frequency, respiratory, and cardiac pulsations, revealing age-related differences.Journal: NeuroImageIn common: fMRI, 10 references, author Qiuting Wen
- [3] doi:10.1016/j.neuroimage.2025.121531
- Effect of brief rest on hemodynamics and CSF oscillations across age.Journal: NeuroImageIn common: fMRI, 7 references, author Qiuting Wen
- [4] doi:10.1186/s12987-024-00572-2
- Coupled pulsatile vascular and paravascular fluid dynamics in the human brain.Journal: Fluids and barriers of the CNSIn common: fMRI, structural MRI / diffusion, 10 references
- [5] doi:10.1002/mrm.70438 [code]
- Quantifying Cardiac, Respiratory, and Low Frequency Components of CSF Motion From fMRI Inflow Effects.Journal: Magnetic resonance in medicineIn common: fMRI, 7 references
- [6] doi:10.1098/rsfs.2024.0024 [code]
- Robust data-driven segmentation of pulsatile cerebral vessels using functional magnetic resonance imaging.Journal: Interface focusIn common: Signal Processing Toolbox, Image Processing Toolbox, Statistics and Machine Learning Toolbox, fMRI, 1 reference, author Adam M Wright
- [7] doi:10.1186/s12987-025-00743-9 [code]
- Imaging blood to periarterial CSF flow coupling using 4D flow MRI and an ultra-high-performance head-only gradient system.Journal: Fluids and barriers of the CNSIn common: Image Processing Toolbox, Statistics and Machine Learning Toolbox, structural MRI / diffusion, 5 references
- [8] doi:10.1177/0271678x221099703
- Increased interictal synchronicity of respiratory related brain pulsations in epilepsy.Journal: Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and MetabolismIn common: fMRI, 6 references
- [9] doi:10.1002/hbm.26128 [code]
- Measuring brain beats: Cardiac-aligned fast functional magnetic resonance imaging signals.Journal: Human brain mappingIn common: Signal Processing Toolbox, Image Processing Toolbox, Statistics and Machine Learning Toolbox, fMRI, 4 references
- [10] doi:10.1073/pnas.2510731123 [code]
- Sleep alters neurovascular and hydrodynamic coupling in the human brain.Journal: Proceedings of the National Academy of Sciences of the United States of AmericaIn common: Signal Processing Toolbox, Image Processing Toolbox, fMRI, 4 references
Contribute
The authors of this paper can claim it, correct its record and validate its tracing map, and the maintainers of its code (its owner, or a public member of its organization) correct what it says of their repository; anyone signed in can ask for its removal. Every request goes to OSCR's own machine, which answers it; your account page follows them.
Sign in with ORCID to claim this paper as one of its authors, correct its record or validate its tracing map: when the paper's metadata lists your ORCID iD, you are recognized at once. Maintainers of its code: sign in with GitHub, then claim the repository on your account page.
Claim this paper
Correct its record
Say what each link of this record is, remove the ones that are not the paper's, add the ones that are missing. The correction becomes a new version of the record, in its Versions section.
Validate its tracing map
You validate the map as this page shows it: 3 repositories of the authors' code, each at its verified commit and with its license, 24 scripts, and 9 matches between paragraphs and code (see the Code and Map sections). It then receives a DOI on Zenodo, with you (your ORCID iD) and OSCR as its creators; the code itself is not deposited.
The map's fingerprint: sha256:aebda596e3186c25…
Add the badge to the code's README
If you are an author or a maintainer of this paper's code, you can add this badge. It says what OSCR knows of the paper (its code, its validated tracing map) and links the code to this page. Paste one of these snippets under the README's title. Keep the two marks around it, so that the badge can be replaced in place and is never added twice. OSCR changes nothing in your repository.
Markdown
<!-- oscr-badge:start -->
[](https://openscicode.org/badge/doi/10.1002/mrm.70446)
<!-- oscr-badge:end -->reStructuredText
.. oscr-badge:start
.. image:: https://openscicode.org/badge/doi/10.1002/mrm.70446.svg
:target: https://openscicode.org/badge/doi/10.1002/mrm.70446
:alt: OSCR
.. oscr-badge:endHTML
<!-- oscr-badge:start -->
<a href="https://openscicode.org/badge/doi/10.1002/mrm.70446"><img src="https://openscicode.org/badge/doi/10.1002/mrm.70446.svg" alt="OSCR"></a>
<!-- oscr-badge:end -->On GitHub, open the README, choose Edit (the pencil), paste the snippet under the title, then "Commit changes".
If you choose to, you can have the badge kept up to date for you, with oscr badge --write from the command line or with the GitHub Action in your repository's workflows. Every other form and option (a card, AsciiDoc, LaTeX, shields.io) is on the badge page.
Request its removal
To ask OSCR to remove this record, the copies of its authors' scripts or its tracing map, use the removal request page: signed in, you say who you are, what to remove and why, then review and confirm the request. Published rules decide every request (how).
Discussion, reproductions, activity
Discussion: code errors and mismatches between the code and the paper about this paper and its code, from readers and its authors, beside the paper and its tracing map.
Report a mismatch between the code and the paper · Report a code error (signed in)
Reproductions: reports from readers who ran the authors' code and did not get the paper's result, what they ran, with which environment, commit and data.
Report a reproduction failure (signed in)
Versions of its code: the releases of its code tied to a version of this paper (the preprint, the accepted manuscript, the version of record…), each with the tracing map versioned with it.
Activity: what happens around this paper: new versions of its record, its map's validation, discussions and reproductions. It opens with sign-in.
