OSCR

Quantifying Cardiac, Respiratory, and Low Frequency Components of CSF Motion From fMRI Inflow Effects.

Code ↔ Paper

3 matches between paragraphs of the paper and lines of its authors' code, computed by the harvester (lexical-v1). Click a colored paragraph or line to see its counterpart.

2 blocks of code here have a permanent identifier (oscr:b:…), listed with the matches below: citable for good, with a page of its own. Select a match and press Cite to copy it. What a block identifier is.

The 3 matches · 2 of them tie a paragraph to a whole file without given lines: weak matches, whose lines are not tinted
  1. [1] § Methods › MRI Protocol ↔ get_protocol_settings.m, the whole file · a weak match · score 0.82 · dummy scans, flip angle, slice thickness, echo, MRI, TR · block oscr:b:0RJF3DJABF7J3-1 · Report a mismatch
  2. [2] § Methods › MRI Protocol ↔ get_protocol_settings.m, the whole file · a weak match · score 0.70 · flip angle, slice thickness, echo, TR, space, scan · block oscr:b:0RJF3DJABF7J3-1 · Report a mismatch
  3. [3] § Methods › Model Validation ↔ investigate_profile.m, lines 50 to 122 · score 0.59 · fitted plug, flow profile, plug flow, velocities, model, signals · block oscr:b:QB1EABJS1N9ZQ-B · Report a mismatch

Paper

Loaded from Europe PMC by your browser; OSCR does not store it: doi.org · Europe PMC

The paper is loaded when this pane is shown.

The authors' code

MATLAB · 43 lines · 1.9 KB · no license · 2 matches

  1. function model_settings = get_protocol_settings(nslices)
  2. % Create a struct with model and protocol settings
  3. model_settings = struct;
  4. model_settings.theta = 80; % flip angle (degrees)
  5. model_settings.TR = 2; % repitition time (s)
  6. model_settings.TE = 30/1000; % echo time (s)
  7. model_settings.T1 = 4.7; % 4.2734; %4.3; % (s) Normal Values of Magnetic Relaxation Parameters of Spine
  8. model_settings.T2 = 1.6; % 1.5776; %2.00; % (s) Components with the Synthetic MRI Sequence
  9. model_settings.ds = 10; % Nr of dummy scans
  10. model_settings.n_slices = nslices; % Nr of excited slices of consideration
  11. model_settings.L = 3.4; % slice thickness (mm)
  12. model_settings.sp = 0.5; % spacing (mm)
  13. model_settings.stp = 20; % number of points per mm for mesh
  14. model_settings.xmin = -(model_settings.n_slices-1)*(model_settings.L+model_settings.sp) + model_settings.sp; % min position
  15. model_settings.xmax = model_settings.n_slices*(model_settings.L+model_settings.sp) - model_settings.sp; % max position
  16. model_settings.x0 = 0:(model_settings.L+model_settings.sp):(model_settings.n_slices-1)*(model_settings.L + model_settings.sp); % ground position slices (mm)
  17. model_settings.dt = 2/37; % Time per slice (s)
  18. model_settings.Nt = 170; %60; %170; % Nr of excitations per slice
  19. model_settings.t0 = 30; % time before excitations
  20. t_ex = zeros(model_settings.Nt + model_settings.ds, model_settings.n_slices); % time at excitation (s)
  21. for i = 1:model_settings.n_slices
  22. j = floor(i/2);
  23. if (mod(i, 2) == 0)
  24. t_ex(:,i) = model_settings.t0 + (18 + j)*model_settings.dt + model_settings.TR*(0:(model_settings.ds + model_settings.Nt-1));
  25. else
  26. t_ex(:,i) = model_settings.t0 + j*model_settings.dt + model_settings.TR*(0:(model_settings.ds + model_settings.Nt-1));
  27. end
  28. end
  29. model_settings.t_ex = t_ex;
  30. end

get_protocol_settings.m at commit 1a22169, no license · at the source

Overview

Authors: Pontus Söderström1, Cecilia Björnfot2,3, Britt M. Andersson1, Jan Malm4, Anders Eklund2,3, Anders Wåhlin1,2,3
  1. Department of Applied Physics and Electronics Umeå University Umeå Sweden
  2. Department of Diagnostics and Intervention, Biomedical Engineering and Radiation Physics Umeå University Umeå Sweden
  3. Umeå Center for Functional Brain Imaging (UFBI), Umeå University Umeå Sweden
  4. Department of Clinical Science, Neurosciences Umeå University Umeå Sweden
Institutions: Umeå University (Sweden)
Journal: Magnetic resonance in medicine, volume 96, issue 4, pages 1916-1928
Dates: received 19 December 2025; accepted 5 May 2026; published online 17 May 2026; in print October 2026
Type: Research article · Language: English
License: CC BY
Identifiers: DOI 10.1002/mrm.70438 · PMID 42143758 · PMCID PMC13418971 · OpenAlex W7161483616
Open access: hybrid, a free copy (OpenAlex)
Status: code verified (how the code is found and verified)
Categories: fMRI (modality), human (organism), methods / tools (subfield)
Methods: Spectral & time-frequency, Smoothing, state filtering, decompositions, Machine learning, Preprocessing, Connectivity, fMRI & imaging, Physiology & signal measures
Keywords: cerebrospinal fluid flow, glymphatic system, inflow effect, quantitative flow assessment, resting‐state fMRI
MeSH: Brain*, Cerebrospinal Fluid*, Magnetic Resonance Imaging*, Aged, Aged, 80 and over, Female, Humans, Male, Motion, Phantoms, Imaging, Reproducibility of Results, Respiration (* major topic)
Journal subjects: Computer Processing and Modeling
Topic: Cerebrospinal fluid and hydrocephalus (Clinical Neurology, Medicine), according to OpenAlex
Funding: Hjärt-Lungfonden (20210653); Vetenskapsrådet (2021‐00711_VR/JPND, 2022‐04263); Stiftelsen för Strategisk Forskning (RMX18‐0152)
Citations: not cited yet (Europe PMC); 66 references in the paper

Abstract

Purpose: Cerebrospinal fluid (CSF) flow oscillations have emerged as a potentially important marker related to brain clearance, but their acquisition often relies on specialized imaging MRI sequences. The purpose of this work was to enable quantitative assessment of CSF flow associated with cardiac, respiratory, and low‐frequency cycles using widely available functional magnetic resonance imaging (fMRI) acquisitions.

Methods: A method was developed to translate fMRI‐derived CSF inflow signals into quantitative flow rates. This approach modeled the spin‐history of an oscillating ensemble of molecules. Validation was performed using phantom experiments with cardiac‐, respiratory‐, and low‐frequency‐like oscillatory flow. The method was further applied to resting‐state data from 48 older adults (68–82 years, 19 women) to characterize CSF flow at the foramen magnum.

Results: Phantom experiments demonstrated excellent correlations between estimated and true velocities for cardiac‐ and respiratory‐like frequencies (r = 0.94 and 0.97, respectively) and moderate correlation for the low‐frequency‐like oscillation (r = 0.58). In the population cohort, median CSF stroke volumes were 0.77 [0.57, 1.09] mL for the cardiac cycle, 0.38 [0.26, 0.88] mL for the respiratory cycle, and 0.26 [0.14, 0.39] mL for the low‐frequency cycle.

Conclusion: The proposed spin‐history modeling method enabled quantitative estimation of CSF flow components using a conventional fMRI dataset and showed that the cardiac cycle dominates CSF motion at the foramen magnum.

Reproduced under the paper's license (CC BY), from the paper cited above.

Repository

Its files are read in the Code ↔ Paper reader above, with 3 matches between paragraphs and lines of code.

Buntess/fMRI-Flow-Quantification

License: none: the authors keep all their rights
State: the link answers, verified on 28 September 2026
Evidence: files inventoried
Commit: 1a221699fed6b9035f1772c0bf7893aa26914c99, 5 May 2026
Languages: MATLAB (12)
Size: 21 files, 12 scripts
Software Heritage: not archived
Found in: the text, “Simulations of CSF Inflow Signal”
Holds: README
Not found: license file, CITATION.cff, environment file, tests, continuous integration, documentation
Tools: Optimization Toolbox (3 files)
Availability: 1 check, the latest on 28 September 2026: the link answers
  • 28 September 2026: the link answers
13 files

Tracing map

Proposed by the machine: these links were found in the paper and verified at the source, without human review. The map will receive a Zenodo DOI once one of the paper's authors has validated it with their ORCID.

What the map holds:

  • 1 repository of the authors' code, each at its verified commit, with its license and how the link was found in the paper;
  • 12 scripts, each with its path and the digest of its content;
  • 3 matches between paragraphs of the paper and lines of the code (method lexical-v1);
  • neither the text of the paper nor the code itself.

Its JSON (tracing-map.json) is deposited on Zenodo with its DOI once the map is validated.

Data

No dataset and no data link were found in the paper.

Data Availability Statement

The data that support the findings of this study are available on request from the corresponding author. The data are not publicly available due to privacy or ethical restrictions.

Reproduced under the paper's license (CC BY), from the paper cited above.

Versions

The history of this record: each version stored by the harvester or made by a correction of its authors or of the maintainers of its code, and what changed in its facts. The texts of the paper (its abstract, its availability statements) are not part of it; versions that changed only those are not listed.

Version 2, 28 September 2026

  • Publisher: n/a → Wiley

Version 1, 28 September 2026: the first record

Recorded: type, language, journal, volume, issue, pages, dates, 6 authors, 5 keywords, 12 MeSH terms, 3 funders, 62 references.

Cite

This paper

Söderström, P., Björnfot, C., Andersson, B. M., Malm, J., Eklund, A., & Wåhlin, A. (2026). Quantifying Cardiac, Respiratory, and Low Frequency Components of CSF Motion From fMRI Inflow Effects. Magnetic resonance in medicine, 96(4), 1916-1928. https://doi.org/10.1002/mrm.70438

BibTeX

@article{soderstrom2026quantifying,
author = {Söderström, Pontus and Björnfot, Cecilia and Andersson, Britt M. and Malm, Jan and Eklund, Anders and Wåhlin, Anders},
title = {{Quantifying Cardiac, Respiratory, and Low Frequency Components of CSF Motion From fMRI Inflow Effects}},
journal = {Magnetic resonance in medicine},
year = {2026},
month = may,
volume = {96},
number = {4},
pages = {1916--1928},
publisher = {Wiley},
issn = {0740-3194},
doi = {10.1002/mrm.70438},
url = {https://doi.org/10.1002/mrm.70438},
pmid = {42143758},
pmcid = {PMC13418971}
}

RIS

TY - JOUR
AU - Söderström, Pontus
AU - Björnfot, Cecilia
AU - Andersson, Britt M.
AU - Malm, Jan
AU - Eklund, Anders
AU - Wåhlin, Anders
TI - Quantifying Cardiac, Respiratory, and Low Frequency Components of CSF Motion From fMRI Inflow Effects
T2 - Magnetic resonance in medicine
J2 - Magn Reson Med
PY - 2026
DA - 2026/05/17
VL - 96
IS - 4
SP - 1916
EP - 1928
SN - 0740-3194
PB - Wiley
DO - 10.1002/mrm.70438
UR - https://doi.org/10.1002/mrm.70438
LA - en
ER -

CSL-JSON

{
"id": "10.1002/mrm.70438",
"type": "article-journal",
"title": "Quantifying Cardiac, Respiratory, and Low Frequency Components of CSF Motion From fMRI Inflow Effects",
"container-title": "Magnetic resonance in medicine",
"author": [
{
"family": "Söderström",
"given": "Pontus"
},
{
"family": "Björnfot",
"given": "Cecilia"
},
{
"family": "Andersson",
"given": "Britt M."
},
{
"family": "Malm",
"given": "Jan"
},
{
"family": "Eklund",
"given": "Anders"
},
{
"family": "Wåhlin",
"given": "Anders"
}
],
"container-title-short": "Magn Reson Med",
"volume": "96",
"issue": "4",
"page": "1916-1928",
"DOI": "10.1002/mrm.70438",
"PMID": "42143758",
"PMCID": "PMC13418971",
"ISSN": "0740-3194",
"publisher": "Wiley",
"URL": "https://doi.org/10.1002/mrm.70438",
"language": "en",
"issued": {
"date-parts": [
[
2026,
5,
17
]
]
}
}

The tracing map gets a citation of its own once an author has validated it and it has a DOI.

Similar papers

The papers with a page that share the most with this one: the tools found in their code, their categories, datasets, cited references and authors, the rarest counting most.

[1] doi:10.1038/s41467-025-66548-4
Human cerebrospinal fluid net flow enhanced by respiration during the awake state.
Journal: Nature communications
In common: 13 references
[2] doi:10.1162/imag.a.9 [code]
Modeling dynamic inflow effects in fMRI to quantify cerebrospinal fluid flow.
Journal: Imaging neuroscience (Cambridge, Mass.)
In common: fMRI, 14 references
[3] doi:10.1073/pnas.2526239123 [code]
Quantitative assessment of flow between cerebrospinal and interstitial fluid compartments in humans.
Journal: Proceedings of the National Academy of Sciences of the United States of America
In common: Optimization Toolbox, 8 references, author Pontus Söderström
[4] doi:10.1016/j.neuroimage.2024.120905
Sex-specific age-related differences in cerebrospinal fluid clearance assessed by resting-state functional magnetic resonance imaging.
Journal: NeuroImage
In common: fMRI, 11 references
[5] doi:10.1186/s12987-025-00743-9 [code]
Imaging blood to periarterial CSF flow coupling using 4D flow MRI and an ultra-high-performance head-only gradient system.
Journal: Fluids and barriers of the CNS
In common: 9 references
[6] doi:10.1073/pnas.2501578122 [code]
Orexin effect on physiological pulsations of the human brain.
Journal: Proceedings of the National Academy of Sciences of the United States of America
In common: 10 references
[7] doi:10.1186/s12987-021-00282-z
The glymphatic hypothesis: the theory and the evidence.
Journal: Fluids and barriers of the CNS
In common: 9 references
[8] doi:10.1002/hbm.26128 [code]
Measuring brain beats: Cardiac-aligned fast functional magnetic resonance imaging signals.
Journal: Human brain mapping
In common: Optimization Toolbox, fMRI, 8 references
[9] doi:10.1371/journal.pbio.3002035
Neural activity induced by sensory stimulation can drive large-scale cerebrospinal fluid flow during wakefulness in humans.
Journal: PLoS biology
In common: 9 references
[10] doi:10.1093/brain/awae411 [code]
Loss of glymphatic homeostasis in heart failure.
Journal: Brain : a journal of neurology
In common: 9 references

Contribute

The authors of this paper can claim it, correct its record and validate its tracing map, and the maintainers of its code (its owner, or a public member of its organization) correct what it says of their repository; anyone signed in can ask for its removal. Every request goes to OSCR's own machine, which answers it; your account page follows them.

Sign in with ORCID to claim this paper as one of its authors, correct its record or validate its tracing map: when the paper's metadata lists your ORCID iD, you are recognized at once. Maintainers of its code: sign in with GitHub, then claim the repository on your account page.

Add the badge to the code's README

OSCR: the badge of this paper

If you are an author or a maintainer of this paper's code, you can add this badge. It says what OSCR knows of the paper (its code, its validated tracing map) and links the code to this page. Paste one of these snippets under the README's title. Keep the two marks around it, so that the badge can be replaced in place and is never added twice. OSCR changes nothing in your repository.

Markdown
<!-- oscr-badge:start -->
[![OSCR](https://openscicode.org/badge/doi/10.1002/mrm.70438.svg)](https://openscicode.org/badge/doi/10.1002/mrm.70438)
<!-- oscr-badge:end -->
reStructuredText
.. oscr-badge:start

.. image:: https://openscicode.org/badge/doi/10.1002/mrm.70438.svg
   :target: https://openscicode.org/badge/doi/10.1002/mrm.70438
   :alt: OSCR

.. oscr-badge:end
HTML
<!-- oscr-badge:start -->
<a href="https://openscicode.org/badge/doi/10.1002/mrm.70438"><img src="https://openscicode.org/badge/doi/10.1002/mrm.70438.svg" alt="OSCR"></a>
<!-- oscr-badge:end -->

If you choose to, you can have the badge kept up to date for you, with oscr badge --write from the command line or with the GitHub Action in your repository's workflows. Every other form and option (a card, AsciiDoc, LaTeX, shields.io) is on the badge page.

Request its removal

To ask OSCR to remove this record, the copies of its authors' scripts or its tracing map, use the removal request page: signed in, you say who you are, what to remove and why, then review and confirm the request. Published rules decide every request (how).

Discussion, reproductions, activity

Discussion: code errors and mismatches between the code and the paper about this paper and its code, from readers and its authors, beside the paper and its tracing map.

Report a mismatch between the code and the paper · Report a code error (signed in)

Reproductions: reports from readers who ran the authors' code and did not get the paper's result, what they ran, with which environment, commit and data.

Report a reproduction failure (signed in)

Versions of its code: the releases of its code tied to a version of this paper (the preprint, the accepted manuscript, the version of record…), each with the tracing map versioned with it.

Activity: what happens around this paper: new versions of its record, its map's validation, discussions and reproductions. It opens with sign-in.