Suppression of Oscillation and Ghosting in RF-Spoiled Gradient-Echo-Based Dynamic Imaging.
Paper
Loaded from Europe PMC by your browser; OSCR does not store it: doi.org · Europe PMC
The paper is loaded when this pane is shown.
The authors' code
MATLAB · 161 lines · 5.3 KB · no license
- clear; close all;
- Nx_voxel = 1; Ny_voxel = 1; SpinperVox = 100;
- Nx_spin = SpinperVox*Nx_voxel; Ny_spin = SpinperVox*Ny_voxel;
- FA = 5; TR = 5e-3;
- N_sample = 64;
- t = gpuArray(linspace(1e-3,3e-3,N_sample+1)');
- T2 = gpuArray(7 * TR * ones(Ny_spin, Nx_spin, N_sample+1));
- t2_exp = exp( -reshape(t,1,1,[]) ./ T2 );
- T1s = gpuArray(400 * TR * ones(Ny_spin, Nx_spin));
- T2s = gpuArray(7 * TR * ones(Ny_spin, Nx_spin));
- t1s_exp = exp( -TR ./ T1s );
- t2s_exp = exp( -TR ./ T2s );
- sp = 50;
- dummy = 2000; line = 64; tp = 100;
- main = tp*line;
- k = 1:1:20000;
- RF_spoiler_all = deg2rad( 0.5 * ((k-1).*k) * sp );
- Gm_de = Nx_voxel*pi;
- Gm_ro = Nx_voxel*2*pi;
- Gm_sp = Nx_voxel*1*pi; % pi 3pi 5pi ...
- Gm_pe = Ny_voxel * gpuArray(reshape(repmat(linspace(-1/2 + 1/line,1/2,line),tp,1),1,[]) * 2*pi);
- %% =========================
- % Precompute static terms
- % =========================
- FA_rad = deg2rad(FA);
- cFA = cos(FA_rad);
- sFA = sin(FA_rad);
- % base phase grids
- rot_de_base = gpuArray(linspace(Gm_de/2,-(Gm_de/2)+(Gm_de/Nx_spin),Nx_spin));
- rot_sp_base = gpuArray(linspace(-Gm_sp/2,Gm_sp/2-(Gm_sp/Nx_spin),Nx_spin));
- rot_dum_ro_base = gpuArray(linspace(-Gm_ro/2,(Gm_ro/2)-(Gm_ro/Nx_spin),Nx_spin));
- rot_ro_base = linspace(0,1,N_sample+1)' * linspace(-Gm_ro/2,(Gm_ro/2)-(Gm_ro/Nx_spin),Nx_spin);
- rot_ro_base = gpuArray(permute(rot_ro_base,[3 2 1])); % 1 x Nx x (N_sample+1)
- % phase-encode base (Ny x 1)
- rot_pe_base = gpuArray(linspace(1/2,-1/2+1/Ny_spin,Ny_spin)'); % Ny x Nx
- % all phase-encode exponentials (Ny x main)
- E_pe_all = exp(-1i * (rot_pe_base * Gm_pe));
- % precompute exponentials
- E_de = exp(-1i * ( rot_de_base)); % Ny x Nx
- E_sp = exp(-1i * (rot_sp_base)); % Ny x Nx
- E_dummy_ro = exp(-1i * (repmat(rot_dum_ro_base,[Ny_spin 1]))); % Ny x Nx
- E_ro = exp(-1i * (rot_ro_base)); % Ny x Nx x (N_sample+1)
- % signal part only uses samples 2:end
- E_ro_sig = reshape(E_ro(:,:,2:end) .* t2_exp(:,:,2:end), [], N_sample); % (Ny*Nx) x N_sample
- E_ro_end = E_ro(:,:,end);
- RF_spoiler = gpuArray(RF_spoiler_all(1:dummy+main));
- Ephi_m = exp(-1i * RF_spoiler); % exp(-i*phi_n)
- Ephi_p = conj(Ephi_m); % exp(+i*phi_n)
- % preallocate
- Mxy_pp = complex(gpuArray.zeros(main,N_sample), gpuArray.zeros(main,N_sample));
- % initial magnetization
- Mxy_TR = complex(gpuArray.zeros(Ny_spin,Nx_spin), gpuArray.zeros(Ny_spin,Nx_spin));
- Mz_TR = gpuArray.ones(Ny_spin,Nx_spin);
- for n = 1 : dummy+main
- % =======================================
- % RF rotation using complex transverse M
- % =======================================
- Mxy = Mxy_TR .* Ephi_m(n); % Rz(-phi)
- Mx = real(Mxy);
- My = imag(Mxy);
- My_rf = cFA .* My + sFA .* Mz_TR;
- Mz = -sFA .* My + cFA .* Mz_TR;
- Mxy = (Mx + 1i*My_rf) .* Ephi_p(n);
- % save post-RF, receiver-demodulated transverse state
- Mxy_mm(n,:) = sum(Mxy .* Ephi_m(n),1)/Ny_spin;
- % ==========
- % Dephasing
- % ==========
- if n > dummy
- idx = n - dummy;
- % Ny x 1
- E_pe = E_pe_all(:,idx);
- % implicit expansion across x
- Mxy_de = Mxy .* (E_de .* E_pe);
- % ======================
- % readout / ADC signal
- % ======================
- sig = reshape(Mxy_de,1,[]) * E_ro_sig; % 1 x N_sample
- Mxy_pp(idx,:) = sig .* Ephi_m(n) / (Nx_spin*Ny_spin);
- % final readout state for next spoiler
- Mxy_end = Mxy_de .* E_ro_end;
- else
- E_pe = 1; % scalar
- Mxy_de = Mxy .* E_de;
- Mxy_end = Mxy_de .* E_dummy_ro;
- end
- % =====================
- % Spoiler + rephasing
- % =====================
- Mxy_sp = Mxy_end .* (E_sp .* conj(E_pe));
- % =====================
- % T1 / T2 relaxation
- % =====================
- Mxy_TR = t2s_exp .* Mxy_sp;
- Mz_TR = t1s_exp .* Mz + (1 - t1s_exp);
- end
- Mxy_echo = reshape(Mxy_pp,tp,line,N_sample);
- image = ifftshift(ifft(fftshift(Mxy_echo,2),[],2),2);
- image = (ifftshift(ifft(fftshift(image,3),[],3),3));
- image_tot = gather(image);
- Mxy_echo_tot = gather(Mxy_echo);
- wait(gpuDevice);
- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
- rot = rot_de_base + rot_dum_ro_base + rot_sp_base;
- figure; plot( rad2deg(rot), abs(squeeze(Mxy_mm(2001,:))),'Color','k','Linewidth',2 );
- xlabel('Precession angle [deg]'); ylabel('Magnitude'); ylim([0 0.15])
- set(gcf,'color',[1 1 1]); set(gca,'TickDir','out','Box','off','Color','None','FontSize',15);
- figure; plot( rad2deg(rot), abs(squeeze(Mxy_mm(2002,:))),'Color','k','Linewidth',2 );
- xlabel('Precession angle [deg]'); ylabel('Magnitude'); ylim([0 0.15])
- set(gcf,'color',[1 1 1]); set(gca,'TickDir','out','Box','off','Color','None','FontSize',15);
- figure; plot( rad2deg(rot), angle(squeeze(Mxy_mm(2001,:))),'Color','k','Linewidth',2 );
- xlabel('Precession angle [deg]'); ylabel('Angle'); ylim([-3.5 3.5])
- set(gcf,'color',[1 1 1]); set(gca,'TickDir','out','Box','off','Color','None','FontSize',15);
- figure; plot( rad2deg(rot), angle(squeeze(Mxy_mm(2002,:))),'Color','k','Linewidth',2 );
- xlabel('Precession angle [deg]'); ylabel('Angle'); ylim([-3.5 3.5])
- set(gcf,'color',[1 1 1]); set(gca,'TickDir','out','Box','off','Color','None','FontSize',15);
Figure1.m at commit 6b0f7d2, no license · at the source
Overview
- Department of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon, Republic of Korea
- Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Republic of Korea
Abstract
The abstract is not reproduced here: the paper's license (CC BY-NC-ND) does not allow it. Read it in the paper, at the publisher or on Europe PMC.
Repository
Its files are read in the Code ↔ Paper reader above.
Goldrmat/MRM_RF-phase-cycle-adapted-cine-averaging
6b0f7d2b4c7cbad986b9c0c6af46a6a4da8e4214, 18 June 2026Availability: 1 check, the latest on 27 September 2026: the link answers
- 27 September 2026: the link answers
6 files
The paper's code and data availability statement is in the Data section.
Tracing map
Proposed by the machine: these links were found in the paper and verified at the source, without human review. The map will receive a Zenodo DOI once one of the paper's authors has validated it with their ORCID.
What the map holds:
- 1 repository of the authors' code, each at its verified commit, with its license and how the link was found in the paper;
- 5 scripts, each with its path and the digest of its content;
- no match between paragraphs and code yet;
- neither the text of the paper nor the code itself.
Its JSON (tracing-map.json) is deposited on Zenodo with its DOI once the map is validated.
Data
No dataset and no data link were found in the paper.
Code and data availability statement
The paper has a code and data availability statement. Its license (CC BY-NC-ND) does not allow reproducing it here; in short, from what the harvester recognized in it:
- it points to the authors' code: Goldrmat/
MRM_RF-phase-cycle-adapt ed-cine-averaging
Read it in the paper: doi.org/10.1002/mrm.70497.
Versions
The history of this record: each version stored by the harvester or made by a correction of its authors or of the maintainers of its code, and what changed in its facts. The texts of the paper (its abstract, its availability statements) are not part of it; versions that changed only those are not listed.
Version 2, 28 September 2026
- Publisher: n/a → Wiley
Version 1, 27 September 2026: the first record
Recorded: type, language, journal, volume, issue, pages, dates, 2 authors, 6 keywords, 13 MeSH terms, 1 funder, 22 references.
Cite
This paper
Keum, J., & Park, J. (2026). Suppression of Oscillation and Ghosting in RF-Spoiled Gradient-Echo-Based Dynamic Imaging. Magnetic resonance in medicine, 96(5), 2177-2187. https://
BibTeX
@article{keum2026suppres
author = {Keum, Jae‐Youn and Park, Jang‐Yeon},
title = {{Suppression of Oscillation and Ghosting in RF-Spoiled Gradient-Echo-Based Dynamic Imaging}},
journal = {Magnetic resonance in medicine},
year = {2026},
month = jul,
volume = {96},
number = {5},
pages = {2177--2187},
publisher = {Wiley},
issn = {0740-3194},
doi = {10.1002/
url = {https://
pmid = {42397159},
pmcid = {PMC13527254}
}
RIS
TY - JOUR
AU - Keum, Jae‐Youn
AU - Park, Jang‐Yeon
TI - Suppression of Oscillation and Ghosting in RF-Spoiled Gradient-Echo-Based Dynamic Imaging
T2 - Magnetic resonance in medicine
J2 - Magn Reson Med
PY - 2026
DA - 2026/
VL - 96
IS - 5
SP - 2177
EP - 2187
SN - 0740-3194
PB - Wiley
DO - 10.1002/
UR - https://
LA - en
ER -
CSL-JSON
{
"id": "10.1002/
"type": "article-journal",
"title": "Suppression of Oscillation and Ghosting in RF-Spoiled Gradient-Echo-Based Dynamic Imaging",
"container-title": "Magnetic resonance in medicine",
"author": [
{
"family": "Keum",
"given": "Jae‐Youn"
},
{
"family": "Park",
"given": "Jang‐Yeon"
}
],
"container-title-short":
"volume": "96",
"issue": "5",
"page": "2177-2187",
"DOI": "10.1002/
"PMID": "42397159",
"PMCID": "PMC13527254",
"ISSN": "0740-3194",
"publisher": "Wiley",
"URL": "https://
"language": "en",
"issued": {
"date-parts": [
[
2026,
7,
3
]
]
}
}
The tracing map gets a citation of its own once an author has validated it and it has a DOI.
Similar papers
The papers with a page that share the most with this one: the tools found in their code, their categories, datasets, cited references and authors, the rarest counting most.
- [1] doi:10.1162/imag_a_00275 [code]
- Limitations of 2-dimensional line-scan MRI for directly measuring neural activity.Journal: Imaging neuroscience (Cambridge, Mass.)In common: Parallel Computing Toolbox, 7 references
- [2] doi:10.1162/imag_a_00120
- Alpha-180 spin-echo-based line-scanning method for high-resolution laminar-specific fMRI in animals.Journal: Imaging neuroscience (Cambridge, Mass.)In common: 4 references
- [3] doi:10.1002/nbm.5280 [code]
- Stimulus-induced rotary saturation imaging of visually evoked response: A pilot study.Journal: NMR in biomedicineIn common: 3 references
- [4] doi:10.1162/imag_a_00477
- Revealing layer-specific cortical activity in human M1 using high-resolution line-scanning fMRI.Journal: Imaging neuroscience (Cambridge, Mass.)In common: 3 references
- [5] doi: [code]
- Diffusion-relaxation MRI as virtual histology: separable microstructural signatures of AD pathology in ex vivo human brainJournal: Research squareIn common: Parallel Computing Toolbox, structural MRI / diffusion, 1 reference
- [6] doi:10.1002/hbm.70624 [code]
- Exploring the Sensitivity Limits of Neuronal Current Imaging With MRI and MEG in the Human Brain.Journal: Human brain mappingIn common: 2 references
- [7] doi:10.1038/s41598-024-63483-0 [code]
- Anisotropic longitudinal water proton relaxation in white matter investigated ex vivo in porcine spinal cord with sample rotation.Journal: Scientific reportsIn common: 2 references
- [8] doi:10.1002/mrm.70114 [code]
- High-resolution deuterium metabolic imaging of the human brain at 9.4 T using phase-cycled balanced SSFP spectral-spatial acquisitions.Journal: Magnetic resonance in medicineIn common: Parallel Computing Toolbox, 1 reference
- [9] doi:10.1038/s41467-026-71506-9 [code]
- UltraFast Layer-Resolved Encoding (uFLARE) functional MRI deciphers bidirectional signaling from spontaneous activity.Journal: Nature communicationsIn common: 2 references
- [10] doi:10.1016/j.isci.2025.112967 [code]
- Contextual responses drive a unique laminar signature in human V1.Journal: iScienceIn common: 2 references
Contribute
The authors of this paper can claim it, correct its record and validate its tracing map, and the maintainers of its code (its owner, or a public member of its organization) correct what it says of their repository; anyone signed in can ask for its removal. Every request goes to OSCR's own machine, which answers it; your account page follows them.
Sign in with ORCID to claim this paper as one of its authors, correct its record or validate its tracing map: when the paper's metadata lists your ORCID iD, you are recognized at once. Maintainers of its code: sign in with GitHub, then claim the repository on your account page.
Claim this paper
Correct its record
Say what each link of this record is, remove the ones that are not the paper's, add the ones that are missing. The correction becomes a new version of the record, in its Versions section.
Validate its tracing map
You validate the map as this page shows it: 1 repository of the authors' code, each at its verified commit and with its license, 5 scripts, and 0 matches between paragraphs and code (see the Code and Map sections). It then receives a DOI on Zenodo, with you (your ORCID iD) and OSCR as its creators; the code itself is not deposited.
The map's fingerprint: sha256:948965873391a7a7…
Add the badge to the code's README
If you are an author or a maintainer of this paper's code, you can add this badge. It says what OSCR knows of the paper (its code, its validated tracing map) and links the code to this page. Paste one of these snippets under the README's title. Keep the two marks around it, so that the badge can be replaced in place and is never added twice. OSCR changes nothing in your repository.
Markdown
<!-- oscr-badge:start -->
[](https://openscicode.org/badge/doi/10.1002/mrm.70497)
<!-- oscr-badge:end -->reStructuredText
.. oscr-badge:start
.. image:: https://openscicode.org/badge/doi/10.1002/mrm.70497.svg
:target: https://openscicode.org/badge/doi/10.1002/mrm.70497
:alt: OSCR
.. oscr-badge:endHTML
<!-- oscr-badge:start -->
<a href="https://openscicode.org/badge/doi/10.1002/mrm.70497"><img src="https://openscicode.org/badge/doi/10.1002/mrm.70497.svg" alt="OSCR"></a>
<!-- oscr-badge:end -->On GitHub, open the README, choose Edit (the pencil), paste the snippet under the title, then "Commit changes".
If you choose to, you can have the badge kept up to date for you, with oscr badge --write from the command line or with the GitHub Action in your repository's workflows. Every other form and option (a card, AsciiDoc, LaTeX, shields.io) is on the badge page.
Request its removal
To ask OSCR to remove this record, the copies of its authors' scripts or its tracing map, use the removal request page: signed in, you say who you are, what to remove and why, then review and confirm the request. Published rules decide every request (how).
Discussion, reproductions, activity
Discussion: code errors and mismatches between the code and the paper about this paper and its code, from readers and its authors, beside the paper and its tracing map.
Report a mismatch between the code and the paper · Report a code error (signed in)
Reproductions: reports from readers who ran the authors' code and did not get the paper's result, what they ran, with which environment, commit and data.
Report a reproduction failure (signed in)
Versions of its code: the releases of its code tied to a version of this paper (the preprint, the accepted manuscript, the version of record…), each with the tracing map versioned with it.
Activity: what happens around this paper: new versions of its record, its map's validation, discussions and reproductions. It opens with sign-in.