OSCR

Suppression of Oscillation and Ghosting in RF-Spoiled Gradient-Echo-Based Dynamic Imaging.

Code ↔ Paper

The paper beside its authors' code: matches between them have not been computed for this paper yet.

Paper

Loaded from Europe PMC by your browser; OSCR does not store it: doi.org · Europe PMC

The paper is loaded when this pane is shown.

The authors' code

MATLAB · 161 lines · 5.3 KB · no license

  1. clear; close all;
  2. Nx_voxel = 1; Ny_voxel = 1; SpinperVox = 100;
  3. Nx_spin = SpinperVox*Nx_voxel; Ny_spin = SpinperVox*Ny_voxel;
  4. FA = 5; TR = 5e-3;
  5. N_sample = 64;
  6. t = gpuArray(linspace(1e-3,3e-3,N_sample+1)');
  7. T2 = gpuArray(7 * TR * ones(Ny_spin, Nx_spin, N_sample+1));
  8. t2_exp = exp( -reshape(t,1,1,[]) ./ T2 );
  9. T1s = gpuArray(400 * TR * ones(Ny_spin, Nx_spin));
  10. T2s = gpuArray(7 * TR * ones(Ny_spin, Nx_spin));
  11. t1s_exp = exp( -TR ./ T1s );
  12. t2s_exp = exp( -TR ./ T2s );
  13. sp = 50;
  14. dummy = 2000; line = 64; tp = 100;
  15. main = tp*line;
  16. k = 1:1:20000;
  17. RF_spoiler_all = deg2rad( 0.5 * ((k-1).*k) * sp );
  18. Gm_de = Nx_voxel*pi;
  19. Gm_ro = Nx_voxel*2*pi;
  20. Gm_sp = Nx_voxel*1*pi; % pi 3pi 5pi ...
  21. Gm_pe = Ny_voxel * gpuArray(reshape(repmat(linspace(-1/2 + 1/line,1/2,line),tp,1),1,[]) * 2*pi);
  22. %% =========================
  23. % Precompute static terms
  24. % =========================
  25. FA_rad = deg2rad(FA);
  26. cFA = cos(FA_rad);
  27. sFA = sin(FA_rad);
  28. % base phase grids
  29. rot_de_base = gpuArray(linspace(Gm_de/2,-(Gm_de/2)+(Gm_de/Nx_spin),Nx_spin));
  30. rot_sp_base = gpuArray(linspace(-Gm_sp/2,Gm_sp/2-(Gm_sp/Nx_spin),Nx_spin));
  31. rot_dum_ro_base = gpuArray(linspace(-Gm_ro/2,(Gm_ro/2)-(Gm_ro/Nx_spin),Nx_spin));
  32. rot_ro_base = linspace(0,1,N_sample+1)' * linspace(-Gm_ro/2,(Gm_ro/2)-(Gm_ro/Nx_spin),Nx_spin);
  33. rot_ro_base = gpuArray(permute(rot_ro_base,[3 2 1])); % 1 x Nx x (N_sample+1)
  34. % phase-encode base (Ny x 1)
  35. rot_pe_base = gpuArray(linspace(1/2,-1/2+1/Ny_spin,Ny_spin)'); % Ny x Nx
  36. % all phase-encode exponentials (Ny x main)
  37. E_pe_all = exp(-1i * (rot_pe_base * Gm_pe));
  38. % precompute exponentials
  39. E_de = exp(-1i * ( rot_de_base)); % Ny x Nx
  40. E_sp = exp(-1i * (rot_sp_base)); % Ny x Nx
  41. E_dummy_ro = exp(-1i * (repmat(rot_dum_ro_base,[Ny_spin 1]))); % Ny x Nx
  42. E_ro = exp(-1i * (rot_ro_base)); % Ny x Nx x (N_sample+1)
  43. % signal part only uses samples 2:end
  44. E_ro_sig = reshape(E_ro(:,:,2:end) .* t2_exp(:,:,2:end), [], N_sample); % (Ny*Nx) x N_sample
  45. E_ro_end = E_ro(:,:,end);
  46. RF_spoiler = gpuArray(RF_spoiler_all(1:dummy+main));
  47. Ephi_m = exp(-1i * RF_spoiler); % exp(-i*phi_n)
  48. Ephi_p = conj(Ephi_m); % exp(+i*phi_n)
  49. % preallocate
  50. Mxy_pp = complex(gpuArray.zeros(main,N_sample), gpuArray.zeros(main,N_sample));
  51. % initial magnetization
  52. Mxy_TR = complex(gpuArray.zeros(Ny_spin,Nx_spin), gpuArray.zeros(Ny_spin,Nx_spin));
  53. Mz_TR = gpuArray.ones(Ny_spin,Nx_spin);
  54. for n = 1 : dummy+main
  55. % =======================================
  56. % RF rotation using complex transverse M
  57. % =======================================
  58. Mxy = Mxy_TR .* Ephi_m(n); % Rz(-phi)
  59. Mx = real(Mxy);
  60. My = imag(Mxy);
  61. My_rf = cFA .* My + sFA .* Mz_TR;
  62. Mz = -sFA .* My + cFA .* Mz_TR;
  63. Mxy = (Mx + 1i*My_rf) .* Ephi_p(n);
  64. % save post-RF, receiver-demodulated transverse state
  65. Mxy_mm(n,:) = sum(Mxy .* Ephi_m(n),1)/Ny_spin;
  66. % ==========
  67. % Dephasing
  68. % ==========
  69. if n > dummy
  70. idx = n - dummy;
  71. % Ny x 1
  72. E_pe = E_pe_all(:,idx);
  73. % implicit expansion across x
  74. Mxy_de = Mxy .* (E_de .* E_pe);
  75. % ======================
  76. % readout / ADC signal
  77. % ======================
  78. sig = reshape(Mxy_de,1,[]) * E_ro_sig; % 1 x N_sample
  79. Mxy_pp(idx,:) = sig .* Ephi_m(n) / (Nx_spin*Ny_spin);
  80. % final readout state for next spoiler
  81. Mxy_end = Mxy_de .* E_ro_end;
  82. else
  83. E_pe = 1; % scalar
  84. Mxy_de = Mxy .* E_de;
  85. Mxy_end = Mxy_de .* E_dummy_ro;
  86. end
  87. % =====================
  88. % Spoiler + rephasing
  89. % =====================
  90. Mxy_sp = Mxy_end .* (E_sp .* conj(E_pe));
  91. % =====================
  92. % T1 / T2 relaxation
  93. % =====================
  94. Mxy_TR = t2s_exp .* Mxy_sp;
  95. Mz_TR = t1s_exp .* Mz + (1 - t1s_exp);
  96. end
  97. Mxy_echo = reshape(Mxy_pp,tp,line,N_sample);
  98. image = ifftshift(ifft(fftshift(Mxy_echo,2),[],2),2);
  99. image = (ifftshift(ifft(fftshift(image,3),[],3),3));
  100. image_tot = gather(image);
  101. Mxy_echo_tot = gather(Mxy_echo);
  102. wait(gpuDevice);
  103. %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
  104. rot = rot_de_base + rot_dum_ro_base + rot_sp_base;
  105. figure; plot( rad2deg(rot), abs(squeeze(Mxy_mm(2001,:))),'Color','k','Linewidth',2 );
  106. xlabel('Precession angle [deg]'); ylabel('Magnitude'); ylim([0 0.15])
  107. set(gcf,'color',[1 1 1]); set(gca,'TickDir','out','Box','off','Color','None','FontSize',15);
  108. figure; plot( rad2deg(rot), abs(squeeze(Mxy_mm(2002,:))),'Color','k','Linewidth',2 );
  109. xlabel('Precession angle [deg]'); ylabel('Magnitude'); ylim([0 0.15])
  110. set(gcf,'color',[1 1 1]); set(gca,'TickDir','out','Box','off','Color','None','FontSize',15);
  111. figure; plot( rad2deg(rot), angle(squeeze(Mxy_mm(2001,:))),'Color','k','Linewidth',2 );
  112. xlabel('Precession angle [deg]'); ylabel('Angle'); ylim([-3.5 3.5])
  113. set(gcf,'color',[1 1 1]); set(gca,'TickDir','out','Box','off','Color','None','FontSize',15);
  114. figure; plot( rad2deg(rot), angle(squeeze(Mxy_mm(2002,:))),'Color','k','Linewidth',2 );
  115. xlabel('Precession angle [deg]'); ylabel('Angle'); ylim([-3.5 3.5])
  116. set(gcf,'color',[1 1 1]); set(gca,'TickDir','out','Box','off','Color','None','FontSize',15);

Figure1.m at commit 6b0f7d2, no license · at the source

Overview

Authors: Jae‐Youn Keum1, Jang‐Yeon Park1,2
ORCID iDs: Jae‐Youn Keum
  1. Department of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon, Republic of Korea
  2. Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Republic of Korea
Institutions: Sungkyunkwan University (South Korea)
Journal: Magnetic resonance in medicine, volume 96, issue 5, pages 2177-2187
Dates: received 19 February 2026; accepted 22 June 2026; published online 3 July 2026; in print November 2026
Type: Research article · Language: English
License: CC BY-NC-ND
Identifiers: DOI 10.1002/mrm.70497 · PMID 42397159 · PMCID PMC13527254 · OpenAlex W7167229765
Open access: hybrid, a free copy (OpenAlex)
Status: code verified (how the code is found and verified)
Categories: structural MRI / diffusion (modality), human (organism)
Keywords: 2D line‐scan, gradient‐echo‐based cine imaging, pseudo‐steady state, RF phase‐cycle‐adapted averaging, RF spoiling, ultrahigh temporal resolution
MeSH: Brain*, Image Processing, Computer-Assisted*, Magnetic Resonance Imaging*, Magnetic Resonance Imaging, Cine*, Algorithms, Artifacts, Computer Simulation, Humans, Image Enhancement, Image Interpretation, Computer-Assisted, Phantoms, Imaging, Radio Waves, Reproducibility of Results (* major topic)
Topic: Advanced MRI Techniques and Applications (Radiology, Nuclear Medicine and Imaging, Medicine), according to OpenAlex
Funding: National Research Foundation of Korea (RS-2023-NR077284, RS‐2023‐NR077284)
Citations: not cited yet (Europe PMC); 27 references in the paper

Abstract

The abstract is not reproduced here: the paper's license (CC BY-NC-ND) does not allow it. Read it in the paper, at the publisher or on Europe PMC.

Repository

Its files are read in the Code ↔ Paper reader above.

Goldrmat/MRM_RF-phase-cycle-adapted-cine-averaging

License: none: the authors keep all their rights
State: the link answers, verified on 27 September 2026
Evidence: files inventoried
Commit: 6b0f7d2b4c7cbad986b9c0c6af46a6a4da8e4214, 18 June 2026
Languages: MATLAB (5)
Size: 10 files, 5 scripts
Software Heritage: not archived
Found in: “Data Availability Statement”
Holds: README
Not found: license file, CITATION.cff, environment file, tests, continuous integration, documentation
Availability: 1 check, the latest on 27 September 2026: the link answers
  • 27 September 2026: the link answers
6 files

The paper's code and data availability statement is in the Data section.

Tracing map

Proposed by the machine: these links were found in the paper and verified at the source, without human review. The map will receive a Zenodo DOI once one of the paper's authors has validated it with their ORCID.

What the map holds:

  • 1 repository of the authors' code, each at its verified commit, with its license and how the link was found in the paper;
  • 5 scripts, each with its path and the digest of its content;
  • no match between paragraphs and code yet;
  • neither the text of the paper nor the code itself.

Its JSON (tracing-map.json) is deposited on Zenodo with its DOI once the map is validated.

Data

No dataset and no data link were found in the paper.

Code and data availability statement

The paper has a code and data availability statement. Its license (CC BY-NC-ND) does not allow reproducing it here; in short, from what the harvester recognized in it:

Read it in the paper: doi.org/10.1002/mrm.70497.

Versions

The history of this record: each version stored by the harvester or made by a correction of its authors or of the maintainers of its code, and what changed in its facts. The texts of the paper (its abstract, its availability statements) are not part of it; versions that changed only those are not listed.

Version 2, 28 September 2026

  • Publisher: n/a → Wiley

Version 1, 27 September 2026: the first record

Recorded: type, language, journal, volume, issue, pages, dates, 2 authors, 6 keywords, 13 MeSH terms, 1 funder, 22 references.

Cite

This paper

Keum, J., & Park, J. (2026). Suppression of Oscillation and Ghosting in RF-Spoiled Gradient-Echo-Based Dynamic Imaging. Magnetic resonance in medicine, 96(5), 2177-2187. https://doi.org/10.1002/mrm.70497

BibTeX

@article{keum2026suppression,
author = {Keum, Jae‐Youn and Park, Jang‐Yeon},
title = {{Suppression of Oscillation and Ghosting in RF-Spoiled Gradient-Echo-Based Dynamic Imaging}},
journal = {Magnetic resonance in medicine},
year = {2026},
month = jul,
volume = {96},
number = {5},
pages = {2177--2187},
publisher = {Wiley},
issn = {0740-3194},
doi = {10.1002/mrm.70497},
url = {https://doi.org/10.1002/mrm.70497},
pmid = {42397159},
pmcid = {PMC13527254}
}

RIS

TY - JOUR
AU - Keum, Jae‐Youn
AU - Park, Jang‐Yeon
TI - Suppression of Oscillation and Ghosting in RF-Spoiled Gradient-Echo-Based Dynamic Imaging
T2 - Magnetic resonance in medicine
J2 - Magn Reson Med
PY - 2026
DA - 2026/07/03
VL - 96
IS - 5
SP - 2177
EP - 2187
SN - 0740-3194
PB - Wiley
DO - 10.1002/mrm.70497
UR - https://doi.org/10.1002/mrm.70497
LA - en
ER -

CSL-JSON

{
"id": "10.1002/mrm.70497",
"type": "article-journal",
"title": "Suppression of Oscillation and Ghosting in RF-Spoiled Gradient-Echo-Based Dynamic Imaging",
"container-title": "Magnetic resonance in medicine",
"author": [
{
"family": "Keum",
"given": "Jae‐Youn"
},
{
"family": "Park",
"given": "Jang‐Yeon"
}
],
"container-title-short": "Magn Reson Med",
"volume": "96",
"issue": "5",
"page": "2177-2187",
"DOI": "10.1002/mrm.70497",
"PMID": "42397159",
"PMCID": "PMC13527254",
"ISSN": "0740-3194",
"publisher": "Wiley",
"URL": "https://doi.org/10.1002/mrm.70497",
"language": "en",
"issued": {
"date-parts": [
[
2026,
7,
3
]
]
}
}

The tracing map gets a citation of its own once an author has validated it and it has a DOI.

Similar papers

The papers with a page that share the most with this one: the tools found in their code, their categories, datasets, cited references and authors, the rarest counting most.

[1] doi:10.1162/imag_a_00275 [code]
Limitations of 2-dimensional line-scan MRI for directly measuring neural activity.
Journal: Imaging neuroscience (Cambridge, Mass.)
In common: Parallel Computing Toolbox, 7 references
[2] doi:10.1162/imag_a_00120
Alpha-180 spin-echo-based line-scanning method for high-resolution laminar-specific fMRI in animals.
Journal: Imaging neuroscience (Cambridge, Mass.)
In common: 4 references
[3] doi:10.1002/nbm.5280 [code]
Stimulus-induced rotary saturation imaging of visually evoked response: A pilot study.
Journal: NMR in biomedicine
In common: 3 references
[4] doi:10.1162/imag_a_00477
Revealing layer-specific cortical activity in human M1 using high-resolution line-scanning fMRI.
Journal: Imaging neuroscience (Cambridge, Mass.)
In common: 3 references
[5] doi: [code]
Diffusion-relaxation MRI as virtual histology: separable microstructural signatures of AD pathology in ex vivo human brain
Journal: Research square
In common: Parallel Computing Toolbox, structural MRI / diffusion, 1 reference
[6] doi:10.1002/hbm.70624 [code]
Exploring the Sensitivity Limits of Neuronal Current Imaging With MRI and MEG in the Human Brain.
Journal: Human brain mapping
In common: 2 references
[7] doi:10.1038/s41598-024-63483-0 [code]
Anisotropic longitudinal water proton relaxation in white matter investigated ex vivo in porcine spinal cord with sample rotation.
Journal: Scientific reports
In common: 2 references
[8] doi:10.1002/mrm.70114 [code]
High-resolution deuterium metabolic imaging of the human brain at 9.4 T using phase-cycled balanced SSFP spectral-spatial acquisitions.
Journal: Magnetic resonance in medicine
In common: Parallel Computing Toolbox, 1 reference
[9] doi:10.1038/s41467-026-71506-9 [code]
UltraFast Layer-Resolved Encoding (uFLARE) functional MRI deciphers bidirectional signaling from spontaneous activity.
Journal: Nature communications
In common: 2 references
[10] doi:10.1016/j.isci.2025.112967 [code]
Contextual responses drive a unique laminar signature in human V1.
Journal: iScience
In common: 2 references

Contribute

The authors of this paper can claim it, correct its record and validate its tracing map, and the maintainers of its code (its owner, or a public member of its organization) correct what it says of their repository; anyone signed in can ask for its removal. Every request goes to OSCR's own machine, which answers it; your account page follows them.

Sign in with ORCID to claim this paper as one of its authors, correct its record or validate its tracing map: when the paper's metadata lists your ORCID iD, you are recognized at once. Maintainers of its code: sign in with GitHub, then claim the repository on your account page.

Add the badge to the code's README

OSCR: the badge of this paper

If you are an author or a maintainer of this paper's code, you can add this badge. It says what OSCR knows of the paper (its code, its validated tracing map) and links the code to this page. Paste one of these snippets under the README's title. Keep the two marks around it, so that the badge can be replaced in place and is never added twice. OSCR changes nothing in your repository.

Markdown
<!-- oscr-badge:start -->
[![OSCR](https://openscicode.org/badge/doi/10.1002/mrm.70497.svg)](https://openscicode.org/badge/doi/10.1002/mrm.70497)
<!-- oscr-badge:end -->
reStructuredText
.. oscr-badge:start

.. image:: https://openscicode.org/badge/doi/10.1002/mrm.70497.svg
   :target: https://openscicode.org/badge/doi/10.1002/mrm.70497
   :alt: OSCR

.. oscr-badge:end
HTML
<!-- oscr-badge:start -->
<a href="https://openscicode.org/badge/doi/10.1002/mrm.70497"><img src="https://openscicode.org/badge/doi/10.1002/mrm.70497.svg" alt="OSCR"></a>
<!-- oscr-badge:end -->

On GitHub, open the README, choose Edit (the pencil), paste the snippet under the title, then "Commit changes".

If you choose to, you can have the badge kept up to date for you, with oscr badge --write from the command line or with the GitHub Action in your repository's workflows. Every other form and option (a card, AsciiDoc, LaTeX, shields.io) is on the badge page.

Request its removal

To ask OSCR to remove this record, the copies of its authors' scripts or its tracing map, use the removal request page: signed in, you say who you are, what to remove and why, then review and confirm the request. Published rules decide every request (how).

Discussion, reproductions, activity

Discussion: code errors and mismatches between the code and the paper about this paper and its code, from readers and its authors, beside the paper and its tracing map.

Report a mismatch between the code and the paper · Report a code error (signed in)

Reproductions: reports from readers who ran the authors' code and did not get the paper's result, what they ran, with which environment, commit and data.

Report a reproduction failure (signed in)

Versions of its code: the releases of its code tied to a version of this paper (the preprint, the accepted manuscript, the version of record…), each with the tracing map versioned with it.

Activity: what happens around this paper: new versions of its record, its map's validation, discussions and reproductions. It opens with sign-in.